Ch 4. CS80 Disk Manager [ MPE/iX Error Messages Manual Volume I ] MPE/iX 5.0 Documentation
MPE/iX Error Messages Manual Volume I
Chapter 4 CS80 Disk Manager
(Subsystem 121)
--------------------------------------------------------------
---------------------------------------------------------------
1 MESSAGE Only the user-specified length of data was
transferred; however, the DEVICE MANAGER attempted
to transfer more for some reason.
CAUSE User requested a data transfer, but the buffer
supplied was zero bytes long.
ACTION Call your support representative.
---------------------------------------------------------------
2 MESSAGE UNLOCK Request was received; however, the DEVICE
MANAGER was already unlocked.
CAUSE Diagnostics attempted to UNLOCK the Device Manager
unnecessarily.
ACTION Call your support representative.
---------------------------------------------------------------
3 MESSAGE RELEASE is ALLOWED for operator requests;
therefore, the disk pack is allowed to be
dismounted.
CAUSE The front panel button used to spin down a disk
pack is disabled.
ACTION None.
---------------------------------------------------------------
4 MESSAGE RELEASE will be denied for operator requests;
therefore, the disk pack can not be dismounted.
CAUSE The front panel button used to spin down a disk
pack is disabled.
ACTION None.
---------------------------------------------------------------
5 MESSAGE A DEVICE UNLOCK was requested, but the device was
not locked.
CAUSE Device reservation for exclusive access was removed
unnecessarily.
ACTION None.
---------------------------------------------------------------
6 MESSAGE DEVICE LOCK was requested, but the device was
already locked by this host.
CAUSE Device reservation for exclusive access attempted,
but it was already granted.
ACTION None.
---------------------------------------------------------------
7 MESSAGE A bit in the CS80 Hardware status information
field was set for which there is no value defined.
CAUSE Device returned an undefined Warning/Info status.
ACTION Call your support representative.
---------------------------------------------------------------
8 MESSAGE The device missed a revolution during this
transfer.
CAUSE Occurs normally on occasion.
ACTION None.
---------------------------------------------------------------
9 MESSAGE The bit in the CS80 hardware status was set,
which indicates that the logs on the device are
full.
CAUSE Error logs in the device are full.
ACTION Call your support representative.
---------------------------------------------------------------
10 MESSAGE The bit in the CS80 hardware status was set,
which indicates that the data in this transfer was
corrected by the device.
CAUSE Data was recovered with little difficulty.
ACTION None.
---------------------------------------------------------------
11 MESSAGE The bit in the CS80 hardware status was set,
which indicates that the data was corrected by the
device with difficulty.
CAUSE Data was recovered, but sector should be spared.
ACTION Call your support representative.
---------------------------------------------------------------
12 MESSAGE The bit in the CS80 Hardware status was set,
which indicates that the data was corrected in more
than one sector during this transfer. The sector
number in the error log is of the first corrected
one, only.
CAUSE Data was recovered, but sectors should be spared.
ACTION Call your support representative.
---------------------------------------------------------------
13 MESSAGE The bit in the CS80 hardware status was set,
indicating that a defective sector was
AUTOMATICALLY SPARED by the device.
CAUSE Device performed automatic sparing. Data was
recovered.
ACTION None.
---------------------------------------------------------------
14 MESSAGE The bit in the CS80 hardware status was set,
indicating that a LATENCY in the data transfer
occurred.
CAUSE Additional rotation of spindle needed.
ACTION None.
---------------------------------------------------------------
15 MESSAGE The bit in the CS80 hardware status was set,
indicating that only one spare track remains on the
disk.
CAUSE Excessive sparing has been necessary with this
media.
ACTION Call your support representative.
---------------------------------------------------------------
16 MESSAGE The bit in the CS80 hardware status was set,
indicating that the device is requesting release to
perform head alignment. The DEVICE MANAGER will
grant.
CAUSE Automatic head alignment/diagnostics was performed.
ACTION None.
---------------------------------------------------------------
17 MESSAGE The bit in the CS80 Hardware status was set,
indicating that the diagnostic frontpanel was
manipulated causing a REQUEST for RELEASE.
CAUSE User activated front panel diagnostics.
ACTION Verify by looking at front panel.
---------------------------------------------------------------
18 MESSAGE The bit in the CS80 hardware status was set,
indicating that the operator button was pushed,
causing a REQUEST for RELEASE.
CAUSE User attempted to spin-down disk pack.
ACTION Either push button back in, or remove pack.
---------------------------------------------------------------
19 MESSAGE An error occurred previously which caused the
request to be RETRIED by the DEVICE MANAGER. The
retry was SUCCESSFUL.
CAUSE I/O was retried.
ACTION None.
---------------------------------------------------------------
20 MESSAGE The DOBIND was successful. However, the DEVICE
ADAPTER MANAGER is of an incorrect revision.
CAUSE Software versioning problem.
ACTION Call your support representative.
---------------------------------------------------------------
21 MESSAGE The DOBIND was successful. However, the
initialization of hardware received a TIMEOUT.
CAUSE Device did not respond when initialization was
attempted.
ACTION Depends if device is supposed to be powered on.
---------------------------------------------------------------
22 MESSAGE The DOBIND was successful. However, the
initialization of hardware received a DEVICE ERROR.
CAUSE Device responded with an initialization error.
ACTION Call your support representative.
---------------------------------------------------------------
191 MESSAGE The subsystem number in the received message was
incorrect, usually during configuration.
CAUSE Configuration problem.
ACTION Verify your configuration and call your support
representative.
---------------------------------------------------------------
192 MESSAGE A BIND request was received, but already was
bound.
CAUSE Configuration problem.
ACTION Verify your configuration and call your support
representative.
---------------------------------------------------------------
193 MESSAGE Data received from LOOPBACK did not match
original data.
CAUSE Hardware problem during loopback test.
ACTION Call your support representative.
---------------------------------------------------------------
194 MESSAGE A request was received which requires the manager
to be locked, but it is not locked.
CAUSE Diagnostics attempted destructive test on
unreserved device.
ACTION Call your support representative.
---------------------------------------------------------------
195 MESSAGE An UNBIND request was received to UNBIND from
incorrect HIGHER MANAGER port number.
CAUSE Unconfiguration process problem.
ACTION Call your support representative.
---------------------------------------------------------------
196 MESSAGE A DO_UNBIND request was received with the
incorrect LOWER MANAGER port number.
CAUSE Unconfiguration process problem.
ACTION Call your support representative.
---------------------------------------------------------------
197 MESSAGE The memory request to RELEASE MEMORY (during Die
request processing) failed.
CAUSE System software response problem.
ACTION Take a system dump.
---------------------------------------------------------------
198 MESSAGE An attempt to UNBIND failed due to pending I/Os
from an external requester, or attempt to DO_UNBIND
failed due to any pending I/Os for this manager.
CAUSE Unconfiguration inhibited as device busy.
ACTION Try again. If the error persists, call your
support representative.
---------------------------------------------------------------
199 MESSAGE Update of the BAD SECTOR TABLE (which lists all
sectors which should be spared because the manager
detected recoverable or unrecoverable read errors)
failed.
CAUSE Hardware problem or power failure during Bad Sector
Table update.
ACTION Call your support representative.
---------------------------------------------------------------
200 MESSAGE BIND of this manager to the DEVICE ADAPTER
MANAGER failed.
CAUSE Initialization of lower level (Device Adapter,
etc.) failed.
ACTION Examine configuration file. Call your support
representative.
---------------------------------------------------------------
201 MESSAGE An attempt to acquire memory for auxiliary data
area failed.
CAUSE System software resource exhausted.
ACTION Take a system dump.
---------------------------------------------------------------
202 MESSAGE An attempt to acquire a message frame failed.
CAUSE System software resource exhausted.
ACTION Take a system dump.
---------------------------------------------------------------
203 MESSAGE Bad parity detected in data transfer.
CAUSE Fiber-optic connected disk has bad parity over
fiber link.
ACTION Call your support representative.
---------------------------------------------------------------
204 MESSAGE User's buffer is incorrect for the request;
either not present, nil pointer, or (for LOOPBACK
only) not a virtual buffer.
CAUSE System problem.
ACTION Call your support representative.
---------------------------------------------------------------
205 MESSAGE An attempt to spare a block resulted in
unexpected data errors in the new block.
CAUSE Device verifies new sector during spare. Detected
new sector was also bad.
ACTION Call your support representative and try sparing
block once again.
---------------------------------------------------------------
206 MESSAGE Request was cancelled by an abort.
CAUSE May have been caused by a power failure.
ACTION None.
---------------------------------------------------------------
207 MESSAGE A TIMEOUT has occurred, indicating that the drive
is not talking to the manager.
CAUSE Device was not responding.
ACTION Check device and cabling; may be due to a power
failure.
---------------------------------------------------------------
208 MESSAGE A request was made of the manager, but the
manager is currently LOCKED by another higher
manager (usually DIAGNOSTICS).
CAUSE Device accessed by diagnostics.
ACTION Terminate "sysdiag" session; try again.
---------------------------------------------------------------
209 MESSAGE An internal table entry in this manager was
inconsistent; couldn't get or release the table
entry desired.
CAUSE Software problem.
ACTION Take a system dump. Call your support
representative.
---------------------------------------------------------------
210 MESSAGE An attempt to release a MESSAGE FRAME failed.
CAUSE System software problem.
ACTION Take a system dump. Call your support
representative.
---------------------------------------------------------------
211 MESSAGE An attempt to SEND a message failed.
CAUSE System software resource depleted.
ACTION Take a system dump. Call your support
representative.
---------------------------------------------------------------
212 MESSAGE An error bit was set in the ACCESS field of the
CS80 hardware status that is undefined.
CAUSE CS80 device status returned invalid information.
ACTION Call your support representative.
---------------------------------------------------------------
213 MESSAGE Either an error bit in the FAULT field of the
CS80 hardware status which is undefined was set, OR
the DEVICE ADAPTER MANAGER returned LLIO_HW_PROBLEM
status, OR Diagnostics previously set the DEVICE
MANAGER state to BROKEN.
CAUSE May be hardware problem.
ACTION Call your support representative.
---------------------------------------------------------------
214 MESSAGE An error bit in the REJECT field of the CS80
hardware status was set which is undefined.
CAUSE CS80 device status returned invalid information.
ACTION Call your support representative.
---------------------------------------------------------------
215 MESSAGE An invalid unit number was returned in the CS80
hardware status.
CAUSE CS80 device status returned invalid information.
ACTION Call your support representative.
---------------------------------------------------------------
216 MESSAGE An invalid QSTAT was returned in CS80 hardware
status.
CAUSE The QSTAT from device was not defined.
ACTION Call your support representative.
---------------------------------------------------------------
217 MESSAGE The DEVICE ADAPTER MANAGER returned a bad status
in the status field of the DAM Reply message.
CAUSE Problem in the device adapter level; could be due
to a power failure.
ACTION Monitor the process.
---------------------------------------------------------------
218 MESSAGE Immediate status indicates link protocol or port
event errors occur.
CAUSE Fiber-optic connected disk interface problem.
Could be due to a power failure.
ACTION If problem persists, call your support
representative.
---------------------------------------------------------------
219 MESSAGE An incorrect META language was specified during
configuration.
CAUSE Configuration or software version incorrect.
ACTION Call your support representative.
---------------------------------------------------------------
220 MESSAGE An invalid hardware address was specified during
configuration.
CAUSE Configuration of device address incorrect or out of
range.
ACTION Examine configuration files.
---------------------------------------------------------------
221 MESSAGE The disk driver has an internal data structure
error.
CAUSE Critical software resource problem.
ACTION Take a system dump. Call your support
representative.
---------------------------------------------------------------
222 MESSAGE The INTERNAL TABLE is inconsistent.
CAUSE Software problem.
ACTION Take a system dump. Call your support
representative.
---------------------------------------------------------------
223 MESSAGE The DEVICE MANAGER received a request which it
could not understand OR is not currently supported.
CAUSE The application attempted an inappropriate action
for the device.
ACTION Take a system dump and call your Hewlett-Packard
Service Representative.
---------------------------------------------------------------
224 MESSAGE A message was received which is inappropriate for
the current DEVICE MANAGER state, (e.g., an I/O
request prior to DOBIND).
CAUSE Software problem.
ACTION Call your support representative.
---------------------------------------------------------------
225 MESSAGE The transaction was aborted due to SYSTEM
POWERFAIL.
CAUSE Power failure occurred while transaction was
active.
ACTION None.
---------------------------------------------------------------
226 MESSAGE The CYCLIC REDUNDANCY CHECK of the data
transaction failed.
CAUSE Transmission problem; possible cabling problem.
ACTION Verify cabling; call your support representative.
---------------------------------------------------------------
227 MESSAGE The ALINK DEVICE ADAPTER is indicating the
fiber-optic link is non-functional, possibly due to
a power failure.
CAUSE Fiber-optic connected disk interface broken. Maybe
due to power failure.
ACTION Monitor the process; if problem persists, call your
support representative.
---------------------------------------------------------------
228 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to access beyond
the END OF VOLUME.
CAUSE Addressed block beyond volume range.
ACTION Should not occur with single volume devices. Call
your support representative.
---------------------------------------------------------------
229 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to access beyond an
END OF FILE.
CAUSE A file mark was detected; should not occur on
disks.
ACTION Call your support representative.
---------------------------------------------------------------
230 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an UNRECOVERABLE DATA ERROR.
The sector number is entered into the BAD SECTOR
TABLE.
CAUSE Data was lost due to bad sectors.
ACTION Call your support representative.
---------------------------------------------------------------
231 MESSAGE The error bit in the CS80 hardware status was
set, which indicates more than one sector had
UNRECOVERABLE DATA ERRORS. The first bad sector
number is placed in the BAD SECTOR NUMBER.
CAUSE Data was lost due to bad sectors.
ACTION Call your support representative.
---------------------------------------------------------------
232 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to read UNITIALIZED
DATA.
CAUSE Data uninitialized at address location.
ACTION Call your support representative.
---------------------------------------------------------------
233 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to write to a "READ
ONLY" device.
CAUSE Device does not allow writes.
ACTION Verify the device is active. Call your support
representative.
---------------------------------------------------------------
234 MESSAGE The error bit in the CS80 hardware status was
set, which indicates the heads are NOT LOADED as
yet.
CAUSE A transient not ready condition existed.
ACTION Power on the device. Call your support
representative.
---------------------------------------------------------------
235 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to SPARE FAILED due
to no more spare sectors available.
CAUSE Spare command failed.
ACTION Call your support representative.
---------------------------------------------------------------
236 MESSAGE The error bit in the CS80 hardware status was
set, which indicates an attempt to access
UNFORMATTED MEDIA.
CAUSE Disk was not initialized.
ACTION Call your support representative.
---------------------------------------------------------------
237 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the CS80 protocol
requested too many operations at one time.
CAUSE Software problem or cabling problem.
ACTION Call your support representative.
---------------------------------------------------------------
238 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the device requires the
I/O to be tried again.
CAUSE Device required I/O; usually due to auto head
alignment.
ACTION None.
---------------------------------------------------------------
239 MESSAGE The error bit in the CS80 hardware was set, which
indicates the device has had power re-applied or
the heads have re-loaded.
CAUSE Device powered-on; head loaded.
ACTION None.
---------------------------------------------------------------
240 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the device needs to align
its heads or run internal diagnostics (RELEASE
REQUIRED).
CAUSE Device determined that automatic head alignment was
required; performed same.
ACTION None.
---------------------------------------------------------------
241 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the diagnostic frontpanel
on the device was accessed (RELEASE REQUIRED).
CAUSE Device allowed front-panel diagnostics to be
executed.
ACTION Determine if front panel was accessed.
---------------------------------------------------------------
242 MESSAGE The error bit in the hardware status was set,
which indicates that the operator unload button was
pushed (RELEASE REQUIRED).
CAUSE Device allowed the operator to spin-down pack.
ACTION Either push button back in, or remove pack.
---------------------------------------------------------------
243 MESSAGE The error bit in the hardware status was set,
which indicates a HARDWARE FAULT detected by
internal diagnostics.
CAUSE Device diagnostics detected hardware problem.
ACTION Call your support representative.
---------------------------------------------------------------
244 MESSAGE The error bit in the CS80 hardware status is set,
which indicates that a HARDWARE FAULT occurred in
the addressed unit of the device.
CAUSE Could be hardware problem, or a transient problem
due to power-on.
ACTION Call your support representative.
---------------------------------------------------------------
245 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that a HARDWARE FAULT occurred
in the device controller.
CAUSE Device hardware problem.
ACTION Call your support representative.
---------------------------------------------------------------
246 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that an error occurred during
a transfer of data between 2 units in the device
(COPY DATA CS80 Command only).
CAUSE This should never occur as this feature is not
supported.
ACTION Call your support representative.
---------------------------------------------------------------
247 MESSAGE The error bit in the CS80 hardware status was
set, which indicates the execution phase length is
not as expected. A REJECT error occurred; could be
cabling.
CAUSE CS80 transaction was incorrect; could be cabling.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
248 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the CS80 Command bytes
were out-of-sequence. A REJECT error occurred;
could be cabling.
CAUSE CS80 transaction was incorrect; could be cabling.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
249 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the parameter field of
the CS80 Command is invalid. A REJECT error
occurred; could be cabling.
CAUSE CS80 transaction was incorrect.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
250 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the value in the
PARAMETERS of the CS80 Command is too large. A
REJECT error occurred; could be cabling.
CAUSE CS80 transaction was incorrect.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
251 MESSAGE The error bit in the CS80 hardware status is set,
which indicates that the value in the ADDRESS field
in the CS80 Command is illegal. A REJECT error
occurred; could be cabling.
CAUSE CS80 transaction was incorrect. The medium address
range was exceeded.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
252 MESSAGE The error bit was set in the CS80 hardware status
was set, which indicates that CS80 Command Volume
or Unit is illegal. A REJECT error occurred; could
be cabling.
CAUSE CS80 protocol was incorrect. The device address
range was exceeded.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
253 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the OPCODE of the CS80
Command bytes is invalid. A REJECT error occurred;
could be cabling.
CAUSE CS80 command bytes could be invalid.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
254 MESSAGE The error bit in the CS80 hardware status is set,
which indicates the PARITY of the CS80 Command
bytes is bad. A REJECT error occurred; could be
cabling.
CAUSE The device detected a parity error.
ACTION Verify that cabling is correct and call your
support representative.
---------------------------------------------------------------
255 MESSAGE Immediate status returned, indicating the HOST
targeted for this I/O did not respond.
CAUSE Fiber-optic disk detected lack of host
communication.
ACTION Verify connection and try again. If problem
persists, call your support representative.
---------------------------------------------------------------
MPE/iX 5.0 Documentation