HP 3000 Manuals

(CIERR) (contd) [ MPE/iX Error Messages Manual Volume I ] MPE/iX 5.0 Documentation


MPE/iX Error Messages Manual Volume I

(CIERR) (contd) 

205          MESSAGE    A FORMAL FILE DESIGNATOR MAY NOT BE A BACK
                      REFERENCED FILE NAME.   (CIERR 205)

           CAUSE      You have used a "backreferenced" filename
                      (*filename) as the formal filename; this is not
                      allowed.

           ACTION     Reenter your command; do not use the "*"
                      backreference in the filename.

---------------------------------------------------------------

206          MESSAGE    A FORMAL FILE DESIGNATOR MAY NOT BE A SYSTEM
                      DEFINED FILE NAME.   (CIERR 206)

           CAUSE      You have used a "system-defined" filename
                      ($filename) as the formal filename; this is not
                      allowed.

           ACTION     Reenter your command; your formal filename must not
                      begin with "$" or any other nonalphabetic
                      character.  Remember that a formal filename must be
                      a unique name, must begin with an alpha character,
                      and may not consist of more than eight alphanumeric
                      characters.

---------------------------------------------------------------

207          MESSAGE    THE FILE COMMAND REQUIRES AT LEAST 2 PARAMETERS.
                      (CIERR 207)

           CAUSE      You have specified less than two parameters in your
                      FILE statement; a minimum of two is required.

           ACTION     Reenter the FILE command; specify at least one
                      parameter in addition to the formal filename.  To
                      review the syntax of this command, invoke the
                      online Help Facility or refer to the MPE/iX 
                      Commands Reference Manual, (32650-90003).

---------------------------------------------------------------

208          MESSAGE     NO PARAMETERS MAY BE SUPPLIED WHEN BACK
                      REFERENCING A FILE.    (CIERR 208)

           CAUSE      You have attempted to specify parameters with your
                      backreference (*filename); this is not allowed.

           ACTION     Reenter your command; either do not use
                      backreferencing, or leave out the parameters.

---------------------------------------------------------------

209          MESSAGE    UNABLE TO FIND A FILE COMMAND FOR FILE !.  (CIERR
                      209)

           CAUSE      You have backreferenced a file (*filename) that was
                      never defined in a FILE statement.

           ACTION     Either define the file in a FILE statement and then
                      reenter your command, or check to be sure your
                      backreferenced filename is spelled correctly.  To
                      check the FILE statements for your session, use the
                      LISTEQ command.

---------------------------------------------------------------

210          MESSAGE    NO PARAMETERS MAY BE SUPPLIED WHEN EQUATING TO
                      $NULL.  (CIERR 210)

           CAUSE      FILE command does not allow any other parameters
                      when the formal file designator is equated to $NULL
                      file.

           ACTION     Reenter the command and do not supply any other
                      parameters.

---------------------------------------------------------------

211          MESSAGE    THE DOMAIN OF A SYSTEM DEFINED FILE IS FIXED BY
                      THE SYSTEM.  PARAMETER IGNORED.  (CIWARN 211)

           CAUSE      You have attempted to specify a domain (either OLD,
                      NEW, or OLDTEMP) for a system-defined file; this is
                      unnecessary since the domain of all system-defined
                      files is set by the system.

           ACTION     No action is required; the system has simply
                      ignored your domain parameter.

---------------------------------------------------------------

212          MESSAGE    EXPECTED A FILE DOMAIN.  (ONE OF OLD, NEW OR
                      OLDTEMP). (CIERR 212)

           CAUSE      You have failed to specify the file domain (either
                      OLD, NEW, or OLDTEMP); this is a required
                      parameter.

           ACTION     Reenter the command; be sure to specify a file
                      domain.  For more information about this parameter,
                      look up the command syntax by invoking the online
                      Help Facility or referring to the MPE/iX Commands 
                      Reference Manual, (32650-90003).

---------------------------------------------------------------

213          MESSAGE    UNKNOWN FILE DOMAIN.  EXPECTED OLD, NEW OR
                      OLDTEMP. (CIERR 213)

           CAUSE      You entered something that the system tried to
                      interpret as a file domain specification, which
                      must be either OLD, NEW, or OLDTEMP.

           ACTION     Reenter your command, specifying OLD, NEW, or
                      OLDTEMP as the file domain.  For more information
                      about this parameter, look up the command syntax by
                      invoking the online Help Facility or referring
                      to the MPE/iX Commands Reference Manual, 
                      (32650-90003).

---------------------------------------------------------------

214          MESSAGE    EXPECTED A SEMICOLON TO START THE PARAMETER LIST.
                      (CIERR 214)

           CAUSE      You omitted a semicolon where the system expected
                      one.

           ACTION     Check your syntax carefully; reenter the command
                      with a semicolon in the appropriate location.  To
                      review the syntax of the command, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003).

---------------------------------------------------------------

215          MESSAGE    EXTRANEOUS DELIMITER IGNORED.  (CIWARN 215)

           CAUSE      You included an extra delimiter (such as a comma or
                      semicolon) where none was called for.

           ACTION     No action is required; the system merely ignored
                      the extra delimiter.  You may wish to note the
                      error for future reference.

---------------------------------------------------------------

216          MESSAGE    THE ! KEYWORD IS NOT APPROPRIATE IN THE CONTEXT
                      OF A BUILD  COMMAND.  (CIERR 216)

           CAUSE      You have used a keyword that is not recognized by
                      the BUILD command.

           ACTION     Check your syntax and reenter your command.  To
                      review the syntax of the command, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003).

---------------------------------------------------------------

217          MESSAGE    THE ! KEYWORD IS NOT APPROPRIATE IN THE CONTEXT
                      OF A SYSTEM DEFINED FILE.  (CIERR 217)

           CAUSE      You have used a keyword that cannot be used when
                      specifying a system defined file.

           ACTION     Check the syntax for the command by invoking the
                      online Help Facility or referring to the MPE/iX 
                      Commands Reference Manual, (32650-90003), and
                      reenter the command.

---------------------------------------------------------------

218          MESSAGE    THE ! KEYWORD IS NOT APPROPRIATE IN THE CONTEXT
                      OF AN OLD FILE.   (CIERR 218)

           CAUSE      You have used a keyword that cannot be used when
                      specifying an "OLD" file.

           ACTION     Check the syntax for the command by invoking the
                      online Help Facility or referring to the MPE/iX 
                      Commands Reference Manual, (32650-90003), and
                      reenter the command.

---------------------------------------------------------------

219          MESSAGE    THE ! KEYWORD IS NOT APPROPRIATE IN THE CONTEXT
                      OF A NEW FILE.   (CIERR 219)

           CAUSE      You have used a keyword that cannot be used when
                      specifying a "NEW" file.

           ACTION     Check the syntax for the command by invoking the
                      online Help Facility or referring to the MPE/iX 
                      Commands Reference Manual, (32650-90003), and
                      reenter the command.

---------------------------------------------------------------

220          MESSAGE    UNKNOWN KEYWORD FOR FILE COMMAND.  (CIERR 220)

           CAUSE      You have used a keyword that the FILE command does
                      not recognize.

           ACTION     Check your syntax and reenter the command.  To
                      review the syntax of the command, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003).

---------------------------------------------------------------

221          MESSAGE    SPECIFICATION OF CCTL OVERRIDES PREVIOUS NOCCTL.
                      (CIWARN 221)

           CAUSE      You have specified CCTL and the system is warning
                      you that a previous specification of NOCCTL is
                      being overridden.

           ACTION     No action is required, unless you change your mind
                      and wish to respecify NOCCTL. The system is merely
                      bringing this issue to your attention.

---------------------------------------------------------------

222          MESSAGE    SPECIFICATION OF NOCCTL OVERRIDES PREVIOUS CCTL.
                      (CIWARN 222)

           CAUSE      You have specified NOCCTL and the system is warning
                      you that your specification of CCTL earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify CCTL rather than NOCCTL, in which case you
                      must reenter the command, omitting the NOCCTL
                      specification.

---------------------------------------------------------------

223          MESSAGE    SPECIFICATION OF TEMP OVERRIDES PREVIOUS DEL.
                      (CIWARN 223)

           CAUSE      You have specified TEMP and the system is warning
                      you that your specification of DEL earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify DEL rather than TEMP, in which case you
                      must reenter the command, omitting the TEMP
                      specification.

---------------------------------------------------------------

224          MESSAGE    SPECIFICATION OF TEMP OVERRIDES PREVIOUS SAVE.
                      (CIWARN 224)

           CAUSE      You have specified TEMP and the system is warning
                      you that your specification of SAVE earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify SAVE rather than TEMP, in which case you
                      must reenter the command, omitting the TEMP
                      specification.

---------------------------------------------------------------

225          MESSAGE    SPECIFICATION OF SAVE OVERRIDES PREVIOUS DEL.
                      (CIWARN 225)

           CAUSE      You have specified SAVE and the system is warning
                      you that your specification of DEL earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify DEL rather than SAVE, in which case you
                      must reenter the command, omitting the SAVE
                      specification.

---------------------------------------------------------------

226          MESSAGE    SPECIFICATION OF SAVE OVERRIDES PREVIOUS TEMP.
                      (CIWARN 226)

           CAUSE      You have specified SAVE and the system is warning
                      you that your specification of TEMP earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify TEMP rather than SAVE, in which case you
                      must reenter the command, omitting the SAVE
                      specification.

---------------------------------------------------------------

227          MESSAGE    SPECIFICATION OF DEL OVERRIDES PREVIOUS TEMP.
                      (CIWARN 227)

           CAUSE      You have specified DEL and the system is warning
                      you that your specification of TEMP earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify TEMP rather than DEL, in which case you
                      must reenter the command, omitting the DEL
                      specification.

---------------------------------------------------------------

228          MESSAGE    SPECIFICATION OF DEL OVERRIDES PREVIOUS SAVE.
                      (CIWARN 228)

           CAUSE      You have specified DEL and the system is warning
                      you that your specification of SAVE earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify SAVE rather than DEL, in which case you
                      must reenter the command, omitting the DEL
                      specification.

---------------------------------------------------------------

229          MESSAGE    SPECIFICATION OF SHR ACCESS OVERRIDES PREVIOUS
                      EXC.  (CIWARN 229)

           CAUSE      You have specified SHR and the system is warning
                      you that your specification of EXC earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify EXC rather than SHR, in which case you
                      must reenter the command, omitting the SHR
                      specification.

---------------------------------------------------------------

230          MESSAGE    SPECIFICATION OF SHR ACCESS OVERRIDES PREVIOUS
                      EAR OR SEMI.  (CIWARN 230)

           CAUSE      You have specified SHR and the system is warning
                      you that your specification of EAR or SEMI earlier
                      in the command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify EAR or SEMI rather than SHR, in which case
                      you must reenter the command, omitting the SHR
                      specification.

---------------------------------------------------------------

231          MESSAGE    SPECIFICATION OF EAR ACCESS OVERRIDES PREVIOUS
                      EXC.  (CIWARN 231)

           CAUSE      You have specified EAR and the system is warning
                      you that your specification of EXC earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify EXC rather than EAR, in which case you
                      must reenter the command, omitting the EAR
                      specification.

---------------------------------------------------------------

232          MESSAGE    SPECIFICATION OF EAR ACCESS OVERRIDES PREVIOUS
                      SHR.  (CIWARN 232)

           CAUSE      You have specified EAR and the system is warning
                      you that your specification of SHR earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify SHR rather than EAR, in which case you
                      must reenter the command, omitting the EAR
                      specification.

---------------------------------------------------------------

233          MESSAGE    SPECIFICATION OF EXC ACCESS OVERRIDES PREVIOUS
                      EAR OR SEMI.  (CIWARN 233)

           CAUSE      You have specified EXC and the system is warning
                      you that your specification of EAR or SEMI earlier
                      in the command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify EAR or SEMI rather than EXC, in which case
                      you must reenter the command, omitting the EXC
                      specification.

---------------------------------------------------------------

234          MESSAGE    SPECIFICATION OF EXC ACCESS OVERRIDES PREVIOUS
                      SHR.  (CIWARN 234)

           CAUSE      You have specified EXC and the system is warning
                      you that your specification of SHR earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify SHR rather than EXC, in which case you
                      must reenter the command, omitting the EXC
                      specification.

---------------------------------------------------------------

235          MESSAGE    SPECIFICATION OF NOBUF OVERRIDES PREVIOUS BUF.
                      (CIWARN 235)

           CAUSE      You have specified NOBUF and the system is warning
                      you that your specification of BUF earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify BUF rather than NOBUF, in which case you
                      must reenter the command, omitting the NOBUF
                      specification.

---------------------------------------------------------------

236          MESSAGE    SPECIFICATION OF MR ACCESS OVERRIDES PREVIOUS
                      NOMR.  (CIWARN 236)

           CAUSE      You have specified MR and the system is warning you
                      that your specification of NOMR earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify NOMR rather than MR, in which case you must
                      reenter the command, omitting the MR specification.

---------------------------------------------------------------

237          MESSAGE    SPECIFICATION OF NOMR ACCESS OVERRIDES PREVIOUS
                      MR.  (CIWARN 237)

           CAUSE      You have specified NOMR and the system is warning
                      you that your specification of MR earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify MR rather than NOMR, in which case you must
                      reenter the command, omitting the NOMR
                      specification.

---------------------------------------------------------------

238          MESSAGE    SPECIFICATION OF MULTI OVERRIDES PREVIOUS
                      NOMULTI.  (CIWARN 238)

           CAUSE      You have specified MULTI and the system is warning
                      you that your specification of NOMULTI earlier in
                      the command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify NOMULTI rather than MULTI, in which case
                      you must reenter the command, omitting the MULTI
                      specification.

---------------------------------------------------------------

239          MESSAGE    SPECIFICATION OF NOMULTI OVERRIDES PREVIOUS
                      MULTI.  (CIWARN 239)

           CAUSE      You have specified NOMULTI and the system is
                      warning you that your specification of MULTI
                      earlier in the command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify MULTI rather than NOMULTI, in which case
                      you must reenter the command, omitting the NOMULTI
                      specification.

---------------------------------------------------------------

240          MESSAGE    SPECIFICATION OF WAIT OVERRIDES PREVIOUS NOWAIT.
                      (CIWARN 240)

           CAUSE      You have specified WAIT and the system is warning
                      you that your specification of NOWAIT earlier in
                      the command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify NOWAIT rather than WAIT, in which case you
                      must reenter the command, omitting the WAIT
                      specification.

---------------------------------------------------------------

241          MESSAGE    SPECIFICATION OF NOWAIT OVERRIDES PREVIOUS WAIT.
                      (CIWARN 241)

           CAUSE      You have specified NOWAIT and the system is warning
                      you that your specification of WAIT earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify WAIT rather than NOWAIT, in which case you
                      must reenter the command, omitting the NOWAIT
                      specification.

---------------------------------------------------------------

242          MESSAGE    THE KEYWORD ! HAS NO SUBPARAMETERS.  (CIERR 242)

           CAUSE      You have entered what the system interprets to be
                      subparameters after a keyword; that keyword has no
                      subparameters.

           ACTION     To review the command syntax, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003); then reenter the
                      command.

---------------------------------------------------------------

243          MESSAGE    EXPECTED AN EQUALS SIGN (=), SEPARATING THE
                      KEYWORD FROM ITS SUBPARAMETERS.  (CIERR 243)

           CAUSE      You omitted required punctuation after the keyword.
                      If you specified subparameters for the keyword, you
                      should have used an equals sign (=).

           ACTION     To review the command syntax, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003); then reenter the
                      command.

---------------------------------------------------------------

244          MESSAGE    ACCESS SPECIFICATION OVERRIDES PREVIOUS ACCESS.
                      (CIWARN 244)

           CAUSE      You have included more than one access
                      specification in your command line; the system is
                      warning you that it is using the last one named.

           ACTION     If you do not wish the system to use the last one
                      named in your command line, reenter the command,
                      omitting the redundancy.

---------------------------------------------------------------

245          MESSAGE    THE ACCESS TYPE IS A REQUIRED SUBPARAMETER OF THE
                      ACCESS KEYWORD.  (CIERR 245)

           CAUSE      You must specify the access type.

           ACTION     Reenter the command, specifying the access type as
                      a subparameter of the ACCESS keyword.  To review
                      the command syntax, invoke the online Help Facility
                      or refer to the MPE/iX Commands Reference Manual, 
                      (32650-90003).

---------------------------------------------------------------

246          MESSAGE    UNKNOWN ACCESS TYPE.  EXPECTED ONE OF IN, OUT,
                      UPDATE, OUTKEEP, APPEND, INOUT.  (CIERR 246)

           CAUSE      The system does not recognize the type of access
                      you have specified.

           ACTION     To review the command syntax, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003); then reenter the
                      command, specifying the appropriate access type.

---------------------------------------------------------------

247          MESSAGE    ACCESS SYNTAX IS ACCESS = access type. NO OTHER
                      PARAMETERS  ALLOWED.  (CIERR 247)

           CAUSE      You have entered something that the system does not
                      recognize.

           ACTION     To review the command syntax, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003); then reenter the
                      command, specifying the appropriate access type.

---------------------------------------------------------------

248          MESSAGE    BUF PARAMETER OVERRIDES PREVIOUS NOBUF.  (CIWARN
                      248)

           CAUSE      You have specified BUF and the system is warning
                      you that your specification of NOBUF earlier in the
                      command line is being overridden.

           ACTION     No action is required, unless you actually want to
                      specify NOBUF rather than BUF, in which case you
                      must reenter the command, omitting the BUF
                      specification.

---------------------------------------------------------------

249          MESSAGE    BUF PARAMETER OVERRIDES PREVIOUS BUF PARAMETER.
                      (CIWARN 249)

           CAUSE      You have included more than one BUF parameter in
                      your command line; the system is warning you that
                      it is using the last one named.

           ACTION     If you do not wish the system to use the last BUF
                      parameter named in your command line, reenter the
                      command, omitting the redundancy.

---------------------------------------------------------------

250          MESSAGE    EXPECTED INTEGER BETWEEN 0 AND 16 AS NUMBER OF
                      BUFFERS.  (CIERR 250)

           CAUSE      You failed to enter an acceptable number of
                      buffers.

           ACTION     You must specify a positive number between 0 and 16
                      to indicate the number of buffers.

---------------------------------------------------------------

251          MESSAGE    EXTRANEOUS PARAMETER.  THE SYNTAX IS BUF=number
                      of buffers.  (CIERR 251)

           CAUSE      You have entered something that the system does not
                      recognize.  The system expects you to specify the
                      number of buffers using the syntax BUF=number

           ACTION     To review the command syntax, invoke the online
                      Help Facility or refer to the MPE/iX Commands 
                      Reference Manual, (32650-90003); then reenter the
                      command following the required syntax.

---------------------------------------------------------------



MPE/iX 5.0 Documentation