HP 3000 Manuals

HP FORTRAN 77/XL [ SORT-MERGE/XL Programmer's Guide ] MPE/iX 5.0 Documentation


SORT-MERGE/XL Programmer's Guide

HP FORTRAN 77/XL 

          Table E-4.  HP FORTRAN 77/XL Equivalents of SORT-MERGE/XL Data Types 

-----------------------------------------------------------------------------------------------
|           |        SORT-MERGE/XL Data Type         |      HP FORTRAN 77/XL Equivalent       |
-----------------------------------------------------------------------------------------------
|     0     | byte (character)                       | CHARACTER*n                            |
|     1     | twos complement (integer):             |                                        |
|           | 2-byte (short integer)                 | INTEGER*2                              |
|           | 4-byte (integer)                       | INTEGER*4                              |
|     2     | HP 3000 floating point:                |                                        |
|           | 4-byte (real)                          | REAL*4                                 |
|           | 8-byte (double precision)              | REAL*8                                 |
|     3     | IEEE Standard floating point:          |                                        |
|           | 4-byte (real)                          | REAL*4                                 |
|           | 8-byte (double precision)              | REAL*8                                 |
|    10     | Character                              | CHARACTER*n                            |
-----------------------------------------------------------------------------------------------


NOTE The variable n refers to an integer number.
Floating point data may be stored in HP 3000 or IEEE Standard format: * IEEE Standard floating point data is the default MPE XL NM (Native Mode) floating point format. * HP 3000 floating point data may also be created by explicit specification in NM. HP 3000 floating point data is the default in MPE XL CM (Compatibility Mode) or on an MPE V-based system.


MPE/iX 5.0 Documentation