HP 3000 Manuals

UWm [ System Debug Reference Manual ] MPE/iX 5.0 Documentation


System Debug Reference Manual

UWm 

Allocates a named user window at the specified address.  The command name
specifies which type of window to define.  User windows are displayed
within the group window. 

Syntax 

     UWA   offset     [name]    Absolute memory relative (ABS)
     UWDB  offset     [name]    DB relative
     UWS   offset     [name]    S relative
     UWQ   offset     [name]    Q relative

     UWD   dst.off    [name]    Data segment and offset

     UWCA  cmabsaddr  [name]   Code (CST) segment and offset
     UWCAX cmabsaddr  [name]   Code (CSTX) segment and offset

     UWV   virtaddr   [name]    Virtual address
     UWZ   realaddr   [name]    Real address

Parameters 

 offset          UWA, UWDB, UWQ, UWS only.  The CM word offset which
                 specifies the relative starting location.

 dst.off         UWD only.  The data segment and offset where to aim the
                 window.

cmabsaddr        UWCA, UWCAX only.  A full CM absolute code address.
                 This code address specifies three necessary items:
                   Either the CST or the CSTX
                   The absolute code segment number
                   The CM word offset within the code segment

                 Absolute code addresses can be specified in two ways:

                  *  As a long pointer (LPTR):

                     UWCA  23.2644     Implicit CST 23.2644
                     UWCAX 5.3204      Implicit CSTX 5.3204

                  *  As a full absolute code pointer (ACPTR):

                     UWCA  CST(2.200)                Explicit CST
                                                     coercion
                     UWCAX CSTX(2.200)               Explicit CSTX
                                                     coercion
                     UWCAX logtoabs(prog(1.20))      Explicit absolute
                                                     conversion

                 The search path used for procedure name lookups is based
                 on the command suffix letter:

                 UWCA             GRP, PUB, LGRP, LPUB, SYS
                 UWCAX            PROG

 virtaddr        UWV only.  A Precision Architecture virtual address.
                 Virtaddr can be a short pointer, a long pointer, or a
                 full logical code pointer.

 realaddr        UWZ only.  A Precision Architecture real memory address.

 name            The name for this user window.  Names are restricted to
                 eight alphanumeric characters.  If name is omitted, the
                 window is named "user".

Examples 

     %cmdebug > UWQ-30 parms 

Create a user window at Q-30 and name it "parms".

     %cmdebug > UWDB+112, globvar 

Create a user window at DB+112 and name it "globvar".

     $nmdebug > UWV SP-30, count 

Create a user window at SP-30 (stack pointer - 30) and name it "count".

Limitations, Restrictions 

Current limit:  10 user-defined windows per group.