System Debug automatically updates all displayed window values after the
completion of every interactive user command list.  In addition, when the
user single steps (SS) the program, or continues (C) program execution
until the next breakpoint is encountered, System Debug automatically
updates the windows.

System Debug knows the current value of each cell in each window on the
screen, and is therefore able to efficiently update only those cells that
have changed since the last update.  Consequently, window updates are
very quick and are not distracting to the user.  When major changes
appear during window updates, these usually reflect a major change in the
program environment, such as a procedure call.

Values that have been modified between updates are automatically flagged
by System Debug by highlighting them in inverse video.  This allows
simple visual recognition of cells that are changing.  The top of stack
area displayed in the frame and stack windows is typically very dynamic.

The user can configure the terminal enhancement used to display these
changing values (refer to the ENV CHANGES command.)  In addition, the
user can configure the terminal enhancement used to display the current
stack marker (refer to the ENV MARKER command.)