HP 3000 Manuals

Parameters for Database Access Screen [ HP ALLBASE/4GL Developer Administration Manual ] MPE/iX 5.0 Documentation


HP ALLBASE/4GL Developer Administration Manual

Parameters for Database Access Screen 

This screen allows you specify the HP TurboIMAGE/iX databases that may be
accessed by an application.  For each database, you must also specify the
user class password that the application will use to access the database.

You can access this screen from the DB Access option on the main menu.

Screen Image 

[]
Field Descriptions Application. Enter the name of the application for which you wish to specify the accessible databases. When you commit this field, a list of all databases currently accessible by the application is displayed on the screen. List of Database Access Parameters. The scroll area on the second half of the screen contains a list of all databases accessible by the application specified in the Application field. If the list is too long to be displayed on the screen, you can move through the list by using the Next and Previous function keys. The user class passwords are not displayed in the list, as a precaution against unauthorised passers-by seeing the screen when it is displayed. If you wish to see the user class password for a database, you must complete the following fields: Database Name. Enter the name of a database accessed by the application. This is the internal HP ALLBASE/4GL name of the database. This database must be defined on the database definition screen before any access parameters can be set for the database. After you enter this field, a window is displayed containing the database access parameter fields relevant to the type of database indicated in the Type field. If the database name already exists on the list of accessible databases, the window fields will contain the current values set for the database. Currently, only the HP TurboIMAGE/iX database window is displayed.
[]
Database Type. This is a display-only field which indicates the database type. A T in this field indicates that the database is an HP TurboIMAGE/iX database. A question mark (?) in this field indicates that the database definition has been deleted by the HP ALLBASE/4GL administrator. In this case, the database must be redefined on the database definition screen before the application can access the database. Action. Enter the code of the action to be performed on the specified database. Choose from one of the following: Code Action A Add a database to the application. C Change or view the database's access parameters. D Delete a database from an application. Password. Enter a password for an HP TurboIMAGE/iX user class. The password must be a valid user class password for the database, as defined by the HP TurboIMAGE/iX administrator. The password that you enter in this field determines the read and write access permissions of the database for this application, for all application developers and end users. This field is optional, and if you leave the field blank, HP TurboIMAGE/iX will interpret the access permissions to be those of user class zero, which has no password. A database password only applies to the specified application. If a database is accessed by more than one application, the password may be different for each application. Function Keys f1 Applic. Defn Cancels the current screen and displays the application definition screen. f2 Database Defn. Cancels the current screen and displays the database definition screen. f3 Previous Displays the previous screenful of databases accessible from the current application. f4 Next Displays the next screenful of databases accessible from the current application. Additional Information Developers cannot reference a database in an application until access to the database is granted to the application on this screen.


MPE/iX 5.0 Documentation