ARITRAP (NM) (changed) [ Introduction to MPE XL for MPE V Programmers Migration Guide ] MPE/iX 5.0 Documentation
Introduction to MPE XL for MPE V Programmers Migration Guide
ARITRAP (NM)
(changed)
The trapstate parameter of the NM version of the ARITRAP intrinsic is a
required 32-bit signed integer passed by value. The parameter size has
been expanded to handle the additional arithmetic traps available to NM
applications. The trapstate parameter represents a value enabling or
disabling arithmetic traps. (An exception is the IEEE Inexact Result
trap, which can only be disabled.)
The CM version of ARITRAP performs as described in the MPE V/E Intrinsics
Reference Manual (32033-90007). The NM version performs as described in
the MPE XL Intrinsics Reference Manual (32650-90028)
MPE/iX 5.0 Documentation