HP 3000 Manuals

FIELDATTR [ SNA IMF Programmer's Reference Manual ] MPE/iX 5.0 Documentation


SNA IMF Programmer's Reference Manual

FIELDATTR 

FIELDATTR 
returns information about the attributes of a specified field. 

Syntax 
___________________________________________________________________
|                                                                 |
|                        I        I         I           I         |
|        FIELDATTR  (terminalid, fieldnum, fieldrow, fieldcolumn, |
|                                                                 |
|                         I              I             I       I  |
|                    protectedattr, numericattr, displayattr, mdt,|
|                                                                 |
|                            I             I         I            |
|                    currentfieldlen, maxfieldlen, result)        |
|                                                                 |
___________________________________________________________________

            

Parameters 

 terminalid (input) 

Integer identifying the terminal.  The  terminalid is returned in a call
to the OPEN3270 intrinsic.

 fieldnum (input) 

Integer specifying the number of the field whose attributes you are
requesting.  Put a zero in  fieldnum if the screen is unformatted (there
are no attribute characters). 

fieldrow (output) 

Integer indicating the row that is the location of the first data
character in the field.  Possible values are as follows:

0 through 11 (480-character screen)
0 through 23 (1920-character screen)
0 through 42 (3440-character screen)

fieldcolumn (output) 

Integer indicating the column that is the location of the first data
character in the field.  Possible values are as follows:

0 through 39 (480-character screen)
0 through 79 (1920-character screen)
0 through 79 (3440-character screen)

protectedattr (output) 

Integer indicating whether the field specified by  fieldnum is protected
or unprotected.  The  protectedattr parameter returns 0 if the screen is
unformatted. 

0 = Unprotected
1 = Protected

numericattr (output) 

Integer indicating whether the field specified by  fieldnum is
alphanumeric or numeric.  The  numericattr parameter returns 0 if the
screen is unformatted. 

0 = Alphanumeric
1 = Numeric

displayattr (output) 

Integer indicating how the field specified by  fieldnum is displayed on
the terminal screen.  The  displayattr parameter returns 0 if the screen
is unformatted. 

0 = Normal display, light pen not detectable 
1 = Normal display, light pen detectable
2 = Intensified display
3 = No display and no print

HP terminals do not support light pens.

mdt (output) 

Integer indicating whether the Modified Data Tag is set for the field
specified by  fieldnum.  The  mdt parameter returns 0 if the screen is
unformatted. 

0 = Modified data tag not set
1 = Modified data tag set

currentfieldlen (output) 

Integer indicating the current length of the field in the internal
buffer.  Length includes all characters plus embedded and leading nulls;
trailing nulls are not included. 

maxfieldlen (output) 

Integer indicating the maximum number of characters the field can
contain.  This is the number of character positions between the current
field attribute character and the next field attribute character.

result (output) 

The following values can be generated by the FIELDATTR intrinsic:

      0 = Successful completion.
      1 = Device not open.
      9 = Host modified screen since the last receive
          request. (MPE V only) 
     11 = Non-existent field number specified.
     22 = BASIC calling sequence error has occurred.
     25 = Intrinsic call made while in split stack mode.
     26 = Intrinsic call made with the parameter value
          out of bounds.
     29 = Called intrinsic with a request already outstanding.
          (No-wait I/O only) 
     30 = Internal error occurred in IMF intrinsic.
     53 = Invalid intrinsic called for data stream mode device.

Description 

The FIELDATTR intrinsic returns information about a specified field of
the internal screen image.  Your program passes the terminal ID and the
field number.  The intrinsic returns the row and column address of the
field in the buffer, the attributes of the field, the maximum number of
characters in the field, the current number of characters in the field,
and a result parameter indicating success or the reason for failure.

Use the FIELDATTR intrinsic in non-transparent mode.

COBOL Calling Sequence 

CALL "CFIELDATTR" USING TERMINALID FIELDNUM FIELDROW FIELDCOLUMN
PROTECTEDATTR NUMERICATTR DISPLAYATTR MDT CURRENTFIELDLEN MAXFIELDLEN
RESULT. (on MPE V and in compatibility mode on MPE XL)

CALL INTRINSIC "FIELDATTR" USING TERMINALID FIELDNUM FIELDROW FIELDCOLUMN
PROTECTEDATTR NUMERICATTR DISPLAYATTR MDT CURRENTFIELDLEN MAXFIELDLEN
RESULT. (in native mode on MPE XL)

All parameters are numeric data items.

FORTRAN Calling Sequence 

CALL FIELDATTR (TERMINALID, FIELDNUM, FIELDROW, FIELDCOLUMN,
PROTECTEDATTR, NUMERICATTR, DISLAYATTR, MDT, CURRENTFIELDLEN,
MAXFIELDLEN, RESULT)

All parameters are integer variables.

BASIC Calling Sequence 

CALL BFIELDATTR (T, N, R0, C0, A1, A2, A3, A4, L5, L6, R) (on MPE V and
in compatibility mode on MPE XL)

CALL FIELDATTR (T, N, R0, C0, A1, A2, A3, A4, L5, L6, R) (in native mode
on MPE XL)

All parameters are integer variables.

SPL Calling Sequence 

FIELDATTR (TERMINALID, FIELDNUM, FIELDROW, FIELDCOLUMN, PROTECTEDATTR,
NUMERICATTR, DISPLAYATTR, MDT, CURRENTFIELDLEN, MAXFIELDLEN, RESULT)

All parameters are integer variables.

Pascal Calling Sequence 

FIELDATTR (TERMINALID, FIELDNUM, FIELDROW, FIELDCOLUMN, PROTECTEDATTR,
NUMERICATTR, DISPLAYATTR, MDT, CURRENTFIELDLEN, MAXFIELDLEN, RESULT);

All parameters are short integer variables.

C/XL Calling Sequence 

FIELDATTR (&TERMINALID, &FIELDNUM, &FIELDROW, &FIELDCOLUMN,
&PROTECTEDATTR, &NUMERICATTR, &DISPLAYATTR, &MDT, &CURRENTFIELDLEN,
&MAXFIELDLEN, &RESULT);

All parameters are of type short.

Pascal Program Excerpts 

Following are excerpts from a Pascal program that calls SNA IMF
intrinsics.  For examples of complete Pascal programs in non-transparent
and transparent modes, see appendix F, "Sample Programs."

     {************************** Global Declarations **************************}

     type
        shortint      = -32768..32767;       { global type, two bytes (half word) }
     .
     .
     .
     var
        terminalid    : shortint;            { value returned by OPEN3270 intrinsic }
        result        : shortint;

     .
     .
     .
     procedure FIELDATTR;  intrinsic;
     .
     .
     .

     {************************** Local Declarations **************************}

     var
        fieldnum          : shortint;         { All FIELDATTR variables }
        fieldrow          : shortint;         { except terminalid and result }
        fieldcolumn       : shortint;         { are local. }
        protectedattr     : shortint;
        numericattr       : shortint;
        displayattr       : shortint;
        mdt               : shortint;
        currentfieldlen   : shortint;
        maxfieldlen       : shortint;
     .
     .
     .

     {************** Variable Initialization and Intrinsic Call **************}

     fieldnum := 2;

     FIELDATTR (terminalid, fieldnum, fieldrow, fieldcolumn, protectedattr,
                numericattr, displayattr, mdt, currentfieldlen, maxfieldlen,
                result);



MPE/iX 5.0 Documentation