JES2 Configuration for NRJE 

Shownbelow is an example of a JES2 configuration for two workstations.

     * *******************************************************************
     * HEWLETT PACKARD      REMOTE DEFINITIONS   (JES 1.3.2 OR 1.3.4)    *
     * *******************************************************************
     *
     LOGON1 APPLID=JES2
     &MAXSESS=100
     &MLBFSIZ=400
     &NUMLOGS=1                     NUMBER OF JES2 VTAM INTERFACES
     &NUMRJE=30
     &NUMLNES=14
     &NUMTPBF=100
     &TPBFSIZ=400
     *
     LINE1 HDUPLEX,TRANSP,UNIT=031,HISPEED
     LINE2 HDUPLEX,TRANSP,UNIT=033
     LINE3 UNIT=SNA,PASSWORD=NRJELN
     LINE4 HDUPLEX,TRANSP,UNIT=034
     LINE5 HDUPLEX,TRANSP,UNIT=035
     LINE6 HDUPLEX,TRANSP,UNIT=036
     LINE7 HDUPLEX,TRANSP,UNIT=037
     LINE8 UNIT=SNA 
     LINE9 UNIT=SNA 
     LINE10 UNIT=SNA 
     LINE11 UNIT=SNA 
     LINE12 UNIT=SNA 
     LINE13 UNIT=SNA 
     LINE14 UNIT=SNA 

     *********************************************************************
     *      NRJE REMOTE WORKSTATION DEFINITIONS                          *
     *********************************************************************
     RMT16 LUTYPE1,BUFSIZE=512,COMP,CONSOLE,NOCMPCT, 
                DISCINTV=0,NUMPR=4,NUMPU=4,NUMRDR=2
           SETUPHDR,SETUPINF,WAITIME=1 
     R16.RD1 CLASS=A,START 
     R16.RD2 CLASS=A,START 
     R16.PR1 AUTO1,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R16.PR2 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R16.PR3 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R16.PR4 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R16.PU1 AUTO,CCTL,CLASS=B,START,LRECL=80
     R16.PU2 AUTO,CCTL,CLASS=B,START,LRECL=80
     R16.PU3 AUTO,CCTL,CLASS=B,START,LRECL=80
     R16.PU4 AUTO,CCTL,CLASS=B,START,LRECL=80
     *
     RMT17 LUTYPE1,BUFSIZE=512,COMP,CONSOLE,NOCMPCT, 
                DISCINTV=0,NUMPR=4,NUMPU=4,NUMRDR=2
           SETUPHDR,SETUPINF,WAITIME=1 
     R17.RD1 CLASS=A,START 
     R17.RD2 CLASS=A,START 
     R17.PR1 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R17.PR2 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R17.PR3 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R17.PR4 AUTO,CCTL,CLASS=A,CKPTLNS=100,CKPTPGS=10,
             START,PRWIDTH=132,UCS=0,SEP 
     R17.PU1 AUTO,CCTL,CLASS=B,START,LRECL=80
     R17.PU2 AUTO,CCTL,CLASS=B,START,LRECL=80
     R17.PU3 AUTO,CCTL,CLASS=B,START,LRECL=80
     R17.PU4 AUTO,CCTL,CLASS=B,START,LRECL=80
     *
     1 This parameter is no longer valid as of JES2 1.3.4.  The
     equivalent work selection (WS) criteria to cause automatic
     selection of data sets with a form other than the one currently
     mounted on the JES2 printer is WS=(/F).

JES3 Configuration for SNA NRJE 

Shownbelow is an example of a JES3 configuration for two workstations.

     *********************************************************************
     *                       REMOTE WORKSTATION                          *
     *********************************************************************
     *
     RJPWS,N=NRJE1,
              RD=02,
              PR=4,
              PU=4,
              C=R,
              P=NODE1,
              PL=2,
              AUTO=N 
     *
     CONSOLE,JNAME=NRJE1,
             TYPE=RJP,
             DEST=NONE,
             LL=80,
             LEVEL=10
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE1PR1
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE1PR2
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE1PR3
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE1PR4
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE1PU1
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE1PU1
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE1PU3
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE1PU4
     *
     RJPWS,N=NRJE2,
           RD=02,
           PR=4,
           PU=4,
           C=R,
           P=NODE1,
           PL=2,
           AUTO=N 
     *
     CONSOLE,JNAME=NRJE2,
             TYPE=RJP,
             DEST=NONE,
             LL=80,
             LEVEL=10
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE2PR1
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE2PR2
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE2PR3
     *
     DEVICE,DTYPE=RMTPRINT,
            JNAME=NRJE2PR4
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE2PU1
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE2PU1
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE2PU3
     *
     DEVICE,DTYPE=RMTPUNCH,
            JNAME=NRJE2PU4

POWER Configuration for NRJE 

Shownbelow is an example of a VSE/POWER configuration for two
workstations.

     RMT001    PRMT     REMOTE=001,
                        TYPE=LUT1,
                        CONSOLE=YES,
                        SESSLIM=6,
                        XLATE=NO 
     *
     RMT002    PRMT     REMOTE=002,
                        TYPE=LUT1,
                        CONSOLE=YES,
                        SESSLIM=6,
                        XLATE=NO 