SDLC Link Shutdown Error Messages [ SNA Link/iX Node Manager's Guide ] MPE/iX 5.0 Documentation
SNA Link/iX Node Manager's Guide
SDLC Link Shutdown Error Messages
Listed below are the messages that might occur when you are stopping the
SDLC link. These messages occur when the SNACONTROL STOP command calls
the WAN_Kill_Module procedure and encounters an error. Depending on the
logging configuration for the SDLC Link subsystem, these messages are
logged to the console, to disk, or both. The messages are logged in this
format:
Linkname = LinkName Event Type = EventType
Log Class = LogClass Path = Path
Error Num = ErrorNumber Status = Status
(Note that LinkName is the same as the name of the node.) The messages
are listed below in numerical order according to ErrorNumber.
51 MESSAGE Could not stop trace.
CAUSE Tracing might have been turned off with the
SNACONTROL TRACEOFF command, but the link
software status indicates that it is on.
ACTION Ignore this problem unless you are experiencing
other problems. If you are, write down the
error information displayed on the console and
call your Hewlett-Packard support contact.
--------------------------------------------------------------------------
52 MESSAGE The link is not in the link table.
CAUSE The node specified in the SNACONTROL STOP
command is not active.
ACTION Unless the specified NodeName parameter is not
correct, no action is required: The link has
already been shut down.
--------------------------------------------------------------------------
53 MESSAGE The link type is not SDLC, LAP-B or RJE.
CAUSE The caller of this module did not set the link
type to SDLC, LAP-B, or RJE BSC. Since you are
using an SDLC link, the link type must be set to
SDLC.
ACTION Write down the error information displayed on
the console and call your Hewlett-Packard
support contact.
--------------------------------------------------------------------------
54 MESSAGE Could not delete the link from the link table.
CAUSE The NodeName specified in the SNACONTROL STOP
command is not in the link table.
ACTION Ensure that the NodeName is correct and try
again. The link might have already been shut
down.
--------------------------------------------------------------------------
55 MESSAGE Could not unconfigure the link from the system.
CAUSE The I/O subsystem does not have any record of
this link being active.
ACTION Ensure that the NodeName specified in the
SNACONTROL STOP command is correct and try
again. The link might have already been shut
down.
--------------------------------------------------------------------------
56 MESSAGE Could not delete the auxiliary buffer pool.
CAUSE Many causes exist; the Status field of the
message provides more-detailed information about
the specific cause of the problem.
ACTION Write down the error information displayed on
the console and call your Hewlett-Packard
support contact.
--------------------------------------------------------------------------
57 MESSAGE Could not determine the PSI path number IO Serv.
CAUSE The I/O subsystem does not have a physical path
for the specified link, and therefore cannot
unconfigure it from the system.
ACTION Ensure that the NodeName specified in the
SNACONTROL STOP command is correct and try
again.
--------------------------------------------------------------------------
MPE/iX 5.0 Documentation